ZHENGZHOU HENGTONG FURNACE CO,. LTD
Glove Box with H2O & O2 Purification System and Hinged Front Window
  • Glove Box with H2O & O2 Purification System and Hinged Front Window
  • Glove Box with H2O & O2 Purification System and Hinged Front Window
0 1

Glove Box with H2O & O2 Purification System and Hinged Front Window

This product is a stainless steel glove box with the hinged type of front door designed for much easy loading and unloading device into the glove-box. The purification cylinder is made of BASF R3-11 Copper Catalyst and Lindy Molecular Sieve in order to achieve a low water and oxygen concentration of lower than 1 ppm, such that experiments can be conducted in a ultra-clean and highly purified gas environment. It is integrated with vapor pressure control system, purity control system, automatic gas purity regeneration control system, and system data log recording. It is widely used in preparing nanomaterials, Li-ion battery materials, catalysts, and metallorganics and perfectly fitted for Lithium-sulfur and lithium metal battery research.

Product Description

This glove box can be customized according to different application scenarios. For example, in the field of electronic manufacturing, glove boxes can be equipped with anti-static devices to prevent static electricity from damaging electronic components. In the pharmaceutical industry, glove boxes can meet strict aseptic requirements and use special disinfection and purification measures. In the field of scientific research, glove boxes can adjust their internal spatial layout and purification system parameters according to specific experimental needs.

With the continuous advancement of technology, the performance of glove boxes is also constantly improving. In the future, we can expect more efficient purification systems, more intelligent control functions, and more user-friendly designs. These improvements will enable glove boxes to be widely used in more fields, providing strong support for technological innovation and industrial development.

 



Product Parameters

Working Voltage

220V AC,50/60HZ

Max.Power Consumption

6KW

Glove Box Chamber

Case Material: Stainless steel

Chamber dimension: 1200 mm L x 740 mm W x 900 mm H

Openable front window panel (tempered glass, 8 mm thick)

Hinged-type door for easy load of devices inside the glove box

 

Chamber Condition

Water concentration: <1 ppm (20°C, 1 atm)

Oxygen concentration: <1 ppm (20°C, 1 atm)

 

Working Gas

Operating gas: Inert gas such as N2, Ar, He
Regenerating gas: Mixture of H2 (5%) and Operating gas
For purification system with only water adsorbing function, Regenerating gas will be the same as Operating gas

Filter System

Organic Solvent Filter System filled with replaceable activated carbon
Built in HEPA filter can eliminate particle size > 0.3um

Gas Purification System

Automated Regeneration Process
Automated water and oxygen removal
Purification Cylinder: made of BASF antioxidant materials and UOP water adsorbent materials Moisture removal

capacity: 1.5KG
Oxygen removal capacity: 180L

Pipeline: 304 stainless steel, KF40, and KF25 ports

 

Leak Rate

<0.05 vol% / hr (depending on oxygen concentration inside the glove box)

 

Pressure Control System

Automatic pressure control by PLC for the Glove Box Chamber

Pressure Range: +/- 12mbar

Manual pressure control is allowed via a foot pedal

 

Air-lock Chamber

Antechamber Dimensions: 360mm(Dia.) x 600mm(L)

Small Chamber Dimensions (for tools): 150 mm(Dia.) x 300m

 

Purging System

Automatic Purging System allows easy operating and reduces gas consumption

Control system

Siemens PLC control system with 6" touch screen display
Water concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
Oxygen concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
Pressure: -2500 to 2500 Pa with an accuracy of 1 Pa

Ports & Fittings

Total seven KF40 ports on the back of the glove box

 

Data

Automatic system data logging

Gloves

A pair of 9 3/4" butyl glove is included

 

Lighting

Built-in fluorescent lamp

 

Product Dimensions

2000mm(L) x 1000mm(W) x 1900mm(H) (91" x 59" x 75")

Shipping Dimension

86"L x 45" Wx 91"H

Shipping Weight

640 kg (1400 lbs)

 

Warranty

One Year limited warranty with lifetime support

Rusting and damage due to improper storage condition or maintenance are not covered by warranty

Gloves are consumable items and are NOT covered by warranty

The Oxygen Sensor is a consumable component NOT covered by warranty.

Storing the sensor to ensure maximum longevity when not used.

Application Notes & Warnings

The interconnections between the glove box chamber and the gas purification system must be unimpeded during the purification cycles. 

The O2 removal rate is largely dependent on the type of purging gas used. For a faster chamber purging process, Nitrogen is preferred over Argon due to its lighter mass

Regularly perform regeneration to maintain optimum purification efficiency. 

The O2 sensor is consumable and its expected lifespan is around one year. We supply a replacement O2 sensor.

 


Note:Glove box can be customized according to customers’ requirements.

Product Description

This glove box can be customized according to different application scenarios. For example, in the field of electronic manufacturing, glove boxes can be equipped with anti-static devices to prevent static electricity from damaging electronic components. In the pharmaceutical industry, glove boxes can meet strict aseptic requirements and use special disinfection and purification measures. In the field of scientific research, glove boxes can adjust their internal spatial layout and purification system parameters according to specific experimental needs.

With the continuous advancement of technology, the performance of glove boxes is also constantly improving. In the future, we can expect more efficient purification systems, more intelligent control functions, and more user-friendly designs. These improvements will enable glove boxes to be widely used in more fields, providing strong support for technological innovation and industrial development.

 



Product Parameters

Working Voltage

220V AC,50/60HZ

Max.Power Consumption

6KW

Glove Box Chamber

Case Material: Stainless steel

Chamber dimension: 1200 mm L x 740 mm W x 900 mm H

Openable front window panel (tempered glass, 8 mm thick)

Hinged-type door for easy load of devices inside the glove box

 

Chamber Condition

Water concentration: <1 ppm (20°C, 1 atm)

Oxygen concentration: <1 ppm (20°C, 1 atm)

 

Working Gas

Operating gas: Inert gas such as N2, Ar, He
Regenerating gas: Mixture of H2 (5%) and Operating gas
For purification system with only water adsorbing function, Regenerating gas will be the same as Operating gas

Filter System

Organic Solvent Filter System filled with replaceable activated carbon
Built in HEPA filter can eliminate particle size > 0.3um

Gas Purification System

Automated Regeneration Process
Automated water and oxygen removal
Purification Cylinder: made of BASF antioxidant materials and UOP water adsorbent materials Moisture removal

capacity: 1.5KG
Oxygen removal capacity: 180L

Pipeline: 304 stainless steel, KF40, and KF25 ports

 

Leak Rate

<0.05 vol% / hr (depending on oxygen concentration inside the glove box)

 

Pressure Control System

Automatic pressure control by PLC for the Glove Box Chamber

Pressure Range: +/- 12mbar

Manual pressure control is allowed via a foot pedal

 

Air-lock Chamber

Antechamber Dimensions: 360mm(Dia.) x 600mm(L)

Small Chamber Dimensions (for tools): 150 mm(Dia.) x 300m

 

Purging System

Automatic Purging System allows easy operating and reduces gas consumption

Control system

Siemens PLC control system with 6" touch screen display
Water concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
Oxygen concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm
Pressure: -2500 to 2500 Pa with an accuracy of 1 Pa

Ports & Fittings

Total seven KF40 ports on the back of the glove box

 

Data

Automatic system data logging

Gloves

A pair of 9 3/4" butyl glove is included

 

Lighting

Built-in fluorescent lamp

 

Product Dimensions

2000mm(L) x 1000mm(W) x 1900mm(H) (91" x 59" x 75")

Shipping Dimension

86"L x 45" Wx 91"H

Shipping Weight

640 kg (1400 lbs)

 

Warranty

One Year limited warranty with lifetime support

Rusting and damage due to improper storage condition or maintenance are not covered by warranty

Gloves are consumable items and are NOT covered by warranty

The Oxygen Sensor is a consumable component NOT covered by warranty.

Storing the sensor to ensure maximum longevity when not used.

Application Notes & Warnings

The interconnections between the glove box chamber and the gas purification system must be unimpeded during the purification cycles. 

The O2 removal rate is largely dependent on the type of purging gas used. For a faster chamber purging process, Nitrogen is preferred over Argon due to its lighter mass

Regularly perform regeneration to maintain optimum purification efficiency. 

The O2 sensor is consumable and its expected lifespan is around one year. We supply a replacement O2 sensor.

 


Note:Glove box can be customized according to customers’ requirements.