high temperature furnace is a desktop muffle furnace with a precision TGA (thermal gravimetric analysis) function. This electric muffle furnace is a cost-effective tool to analyze the phase transition of various oxide compounds from 100°C to 1700°C in large quantity samples (250g max) under air ambient conditions.
HTMF-1700-TGA high temperature furnace is a desktop muffle furnace (8L) with a precision TGA (thermal gravimetric analysis) function. This electric muffle furnace is a cost-effective tool to analyze the phase transition of various oxide compounds from 100°C to 1700°C in large quantity samples (250g max) under air ambient conditions.
Furnace Structure | Three types of size heating chambers are selectable: 120x120x120mm (1.7L) 150 x150 x150 mm (3.6L) 200 x 200 x 200mm (8L) (Demonstrated sample) High-purity alumina fiber insulation surrounding the chamber provides maximum energy efficiency. Heavy duty double layer structure with a cooling fan to keep furnace exteriors safe to touch. Double-layer steel case with forced-air cooling to ensure lower safer face temperature. One φ30mm venting port is built on top of the furnace One φ6mm air inlet is located at one side of the furnace. |
Temperature | Maximum Temperature: 1700℃ (≤30min) Continuous Working Temperature: 1600℃ Recommend Heating Rate: ≤10℃/min Temperature accuracy: +/- 0.1ºC Heating element: silicon molybdenum rod Thermocouple: B Type |
Temperature Controller | Eurotherm 3000 precision temperature controller with 24-segment programmable Over-temperature protection and alarm allow for operation without attendant(s). +/- 1 ºC temperature accuracy. B-type thermocouples Software is included and integrated with a force sensor One laptop is included as a control panel. |
Electronic Balance | A precision electronic balance is located at bottom of the heating chamber with a 0.01 g resolution The alumina crucible is set on the balance via an alumina rod Sample amount: 10 g minimum; 250 g maximum. Force Sensor output data will connect to the laptop to show the weight change curve with the temperature RS485 port and operation software is included |
Crucibles | One 120 ml alumina crucible is included. Please click Pic. 1 to order more You may click Pic. 2 to choose ZrO2, BN, or Y2O3 crucible based on your application The customized crucible is available upon request |
Power | 220V Single Phase, 50Hz 5200W Note: Power cable included but without a plug. Please install a plug on your own according to your country or your lab requirement. |
Warranty | One-year limited warranty (Consumable parts such as heating elements, processing tubes, and o-rings are not covered by the warranty, please order the replacement at related products below.) |
HTMF-1700-TGA high temperature furnace is a desktop muffle furnace (8L) with a precision TGA (thermal gravimetric analysis) function. This electric muffle furnace is a cost-effective tool to analyze the phase transition of various oxide compounds from 100°C to 1700°C in large quantity samples (250g max) under air ambient conditions.
Furnace Structure | Three types of size heating chambers are selectable: 120x120x120mm (1.7L) 150 x150 x150 mm (3.6L) 200 x 200 x 200mm (8L) (Demonstrated sample) High-purity alumina fiber insulation surrounding the chamber provides maximum energy efficiency. Heavy duty double layer structure with a cooling fan to keep furnace exteriors safe to touch. Double-layer steel case with forced-air cooling to ensure lower safer face temperature. One φ30mm venting port is built on top of the furnace One φ6mm air inlet is located at one side of the furnace. |
Temperature | Maximum Temperature: 1700℃ (≤30min) Continuous Working Temperature: 1600℃ Recommend Heating Rate: ≤10℃/min Temperature accuracy: +/- 0.1ºC Heating element: silicon molybdenum rod Thermocouple: B Type |
Temperature Controller | Eurotherm 3000 precision temperature controller with 24-segment programmable Over-temperature protection and alarm allow for operation without attendant(s). +/- 1 ºC temperature accuracy. B-type thermocouples Software is included and integrated with a force sensor One laptop is included as a control panel. |
Electronic Balance | A precision electronic balance is located at bottom of the heating chamber with a 0.01 g resolution The alumina crucible is set on the balance via an alumina rod Sample amount: 10 g minimum; 250 g maximum. Force Sensor output data will connect to the laptop to show the weight change curve with the temperature RS485 port and operation software is included |
Crucibles | One 120 ml alumina crucible is included. Please click Pic. 1 to order more You may click Pic. 2 to choose ZrO2, BN, or Y2O3 crucible based on your application The customized crucible is available upon request |
Power | 220V Single Phase, 50Hz 5200W Note: Power cable included but without a plug. Please install a plug on your own according to your country or your lab requirement. |
Warranty | One-year limited warranty (Consumable parts such as heating elements, processing tubes, and o-rings are not covered by the warranty, please order the replacement at related products below.) |