ZHENGZHOU HENGTONG FURNACE CO,. LTD
Hot-Wall Retort Furnace for heat treatment with gas
  • Hot-Wall Retort Furnace for heat treatment with gas
  • Hot-Wall Retort Furnace for heat treatment with gas
0 1

Hot-Wall Retort Furnace for heat treatment with gas

HT gas tight retort furnace is equipped with direct or indirect heating depending on temperature. This hot wall retort furnace is perfectly suited for various heat treatment processes requiring a defined protective or a reaction gas atmosphere with a slight overpressure. These compact models can also be laid out for heat treatment under vacuum up to 600 °C. The hot-wall retort furnace chamber consists of a gas tight retort with water cooling around the door to protect the special sealing.

  • Price
    0
total sales0
evaluate0
Qty
- +

Pledge: genuine guarantee,speed refund,gift insurance,seven days no reason to return

  • Product Details
  • HT gas tight retort furnace is equipped with direct or indirect heating depending on temperature. This hot wall retort furnace is perfectly suited for various heat treatment processes requiring a defined protective or a reaction gas atmosphere with a slight overpressure. These compact models can also be laid out for heat treatment under vacuum up to 600 °C. The hot-wall retort furnace chamber consists of a gas tight retort with water cooling around the door to protect the special sealing. With the corresponding safety technology, retort furnaces are also suitable for applications under reaction gases, such as hydrogen or, in combination with the IDB package, for inert debinding or for pyrolysis processes.

     

    Different model versions are available depending on the temperature range:

     

    Models NRA /06 with Tmax 600 °C

    Heating elements located inside the retort

    Retort made of 1.4571 (X6CrNiMoTi 17-12-2)

    Air circulation fan and baffle for directed gas flow

    Insulation made of mineral wool

    hot-wall retort furnace temperature control with measurement inside the retort

    Models NRA/09 with Tmax 900 °C

    Design like models NRA/06 with following differences:

    Outside heating with heating elements around the retort

    Retort made of 1.4828 (X15CrNiSi 20-12)

    Multi-layer refractory insulation and micro-porous panel material

    Furnace temperature control with measurement outside the retort

    Models NR/11 with Tmax 1100 °C

    Design like models NRA /09 with following differences:

    Retort made of 1.4841 (X15CrNiSi 25-21)

    Without gas-circulation and baffles

    Welded support brackets

    Standard Equipment

    Compact design with integrated control and gas supply up to gas tight retort furnace.

    Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumina silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.

    Swivel door hinged on right side

    Open cooling water system

    Control divided into several heating zones

    Temperature uniformity up to +/ 8 °C according to DIN 17052-1 in the empty work space see page 85

    Gas supply system for one non-flammable protective or reaction gas with flow meter and magnetic valve

    Defined application within the constraints of the operating instructions

     

    Upgrade for other non-flammable gases

    Mass flow controller MFC

    Process controls H3700, H1700 (PLC) including remote maintenance module

    Temperature control as charge control with temperature measurement inside and outside the retort

    Indirect and/or direct cooling

    Heat exchanger with closed-loop cooling water circuit for door cooling

    Oxygen sensor and dew point sensor

    Parallel swing door or electric bayonet catch

    Retort, made of 2.4633 for Tmax 1150 °C

    External switchgear with or without cabinet cooling

    Charge support or custom-built charging trolley

    Temperature uniformity optimized according to DIN 17052 or AMS2750F to +/ 5 °C in empty work space.


    HT gas tight retort furnace is equipped with direct or indirect heating depending on temperature. This hot wall retort furnace is perfectly suited for various heat treatment processes requiring a defined protective or a reaction gas atmosphere with a slight overpressure. These compact models can also be laid out for heat treatment under vacuum up to 600 °C. The hot-wall retort furnace chamber consists of a gas tight retort with water cooling around the door to protect the special sealing. With the corresponding safety technology, retort furnaces are also suitable for applications under reaction gases, such as hydrogen or, in combination with the IDB package, for inert debinding or for pyrolysis processes.

     

    Different model versions are available depending on the temperature range:

     

    Models NRA /06 with Tmax 600 °C

    Heating elements located inside the retort

    Retort made of 1.4571 (X6CrNiMoTi 17-12-2)

    Air circulation fan and baffle for directed gas flow

    Insulation made of mineral wool

    hot-wall retort furnace temperature control with measurement inside the retort

    Models NRA/09 with Tmax 900 °C

    Design like models NRA/06 with following differences:

    Outside heating with heating elements around the retort

    Retort made of 1.4828 (X15CrNiSi 20-12)

    Multi-layer refractory insulation and micro-porous panel material

    Furnace temperature control with measurement outside the retort

    Models NR/11 with Tmax 1100 °C

    Design like models NRA /09 with following differences:

    Retort made of 1.4841 (X15CrNiSi 25-21)

    Without gas-circulation and baffles

    Welded support brackets

    Standard Equipment

    Compact design with integrated control and gas supply up to gas tight retort furnace.

    Exclusive use of insulation materials without categorization according to EC Regulation No 1272/2008 (CLP). This explicitly means that alumina silicate wool, also known as “refractory ceramic fiber” (RCF), which is classified and possibly carcinogenic, is not used.

    Swivel door hinged on right side

    Open cooling water system

    Control divided into several heating zones

    Temperature uniformity up to +/ 8 °C according to DIN 17052-1 in the empty work space see page 85

    Gas supply system for one non-flammable protective or reaction gas with flow meter and magnetic valve

    Defined application within the constraints of the operating instructions

     

    Upgrade for other non-flammable gases

    Mass flow controller MFC

    Process controls H3700, H1700 (PLC) including remote maintenance module

    Temperature control as charge control with temperature measurement inside and outside the retort

    Indirect and/or direct cooling

    Heat exchanger with closed-loop cooling water circuit for door cooling

    Oxygen sensor and dew point sensor

    Parallel swing door or electric bayonet catch

    Retort, made of 2.4633 for Tmax 1150 °C

    External switchgear with or without cabinet cooling

    Charge support or custom-built charging trolley

    Temperature uniformity optimized according to DIN 17052 or AMS2750F to +/ 5 °C in empty work space.