Liquid Vaporization Systems with Temperature and Pressure Control for CVD & DLCVD

LVD-F1 is a precision & cost-effective liquid evaporating delivery system for lab scale CVD or DLCVD, which can carry all types of liquids, such as ETOH, SnCl4, TiCl4r, SiHCl3, and Zn(C2H5)2, etc. Liquid Vaporization Systems with Temperature and Pressure Control is an ideal tool for the CVD processing of nanowire and film together with electric furnace system in material research.

  • Price
    0
total sales0
evaluate0
Qty
- +

Pledge: genuine guarantee,speed refund,gift insurance,seven days no reason to return

  • Product Details
  • LVD-F1 is a precision & cost-effective liquid evaporating delivery system for lab scale CVD or DLCVD, which can carry all types of liquids, such as ETOH, SnCl4, TiCl4r, SiHCl3, and Zn(C2H5)2, etc., without worrying about corrosion. Liquid Vaporization Systems with Temperature and Pressure Control is an ideal tool for the CVD processing of nanowire and film together with electric furnace system in material research.

     

    Product Structure

    Stainless steel

    Power Input

    220V 50Hz

    2200 W Power consumption

    110V is available with a transformer

    Liquid Flow Control

    Precision digital control with +/- 0.5% FS accuracy

    Flow rate arrange: 0 - 10 ml/minute adjustable (min. rate: 0.1 ml/min)

    The liquid can be soaked from a container automatically.

    Heater Temperature controller

    Liquid and carrying gas go through an SS316 coil, which is heated by a built-in small furnace up to 550ºC

    One heating tube is included to prevent output vapor from condensing on tube or flange (max. temperature 200ºC). The heating tube could be generated as secondary heating to prevent the liquid or gas cool down while passing through the tube.

    Single Set point temperature controller (not programmable)

    Gas flow control

    Carrying gas (inert gas) is controlled by a precision float flow-meter (200 - 2000 mL/min adjustable). The optional digital mass flow controller is available at extra cost.

    Pressure gauge built in front panel

    Two SS needle valves are installed to control gas in and out

    Vapor Gas outlet tube fitting size:  1/4"OD

    Note: 1/4'' PTFE tube, 1/4'' SS tube, and beaker are not included, customers need to prepare them according to the experimental needs.

    The inert gas tank is required to deliver vapor 

    Application Note

    This system can fit with all MTI tube furnaces and CVD furnaces, click the picture below to see how, and choose a furnace at " CVD Furnace System" 

    Dimension & Weight

    Heater & Gas Control Unit:   390L x 420W x 360H, mm

    Total height with the tube supporting stand: 750mm

    Net weight:  18 Kg

    Warranty

    One year limited and extended warranty available upon request


    LVD-F1 is a precision & cost-effective liquid evaporating delivery system for lab scale CVD or DLCVD, which can carry all types of liquids, such as ETOH, SnCl4, TiCl4r, SiHCl3, and Zn(C2H5)2, etc., without worrying about corrosion. Liquid Vaporization Systems with Temperature and Pressure Control is an ideal tool for the CVD processing of nanowire and film together with electric furnace system in material research.

     

    Product Structure

    Stainless steel

    Power Input

    220V 50Hz

    2200 W Power consumption

    110V is available with a transformer

    Liquid Flow Control

    Precision digital control with +/- 0.5% FS accuracy

    Flow rate arrange: 0 - 10 ml/minute adjustable (min. rate: 0.1 ml/min)

    The liquid can be soaked from a container automatically.

    Heater Temperature controller

    Liquid and carrying gas go through an SS316 coil, which is heated by a built-in small furnace up to 550ºC

    One heating tube is included to prevent output vapor from condensing on tube or flange (max. temperature 200ºC). The heating tube could be generated as secondary heating to prevent the liquid or gas cool down while passing through the tube.

    Single Set point temperature controller (not programmable)

    Gas flow control

    Carrying gas (inert gas) is controlled by a precision float flow-meter (200 - 2000 mL/min adjustable). The optional digital mass flow controller is available at extra cost.

    Pressure gauge built in front panel

    Two SS needle valves are installed to control gas in and out

    Vapor Gas outlet tube fitting size:  1/4"OD

    Note: 1/4'' PTFE tube, 1/4'' SS tube, and beaker are not included, customers need to prepare them according to the experimental needs.

    The inert gas tank is required to deliver vapor 

    Application Note

    This system can fit with all MTI tube furnaces and CVD furnaces, click the picture below to see how, and choose a furnace at " CVD Furnace System" 

    Dimension & Weight

    Heater & Gas Control Unit:   390L x 420W x 360H, mm

    Total height with the tube supporting stand: 750mm

    Net weight:  18 Kg

    Warranty

    One year limited and extended warranty available upon request