ZHENGZHOU HENGTONG FURNACE CO,. LTD
1600 C Macro TGA tube furnace with Vacuum and Atmosphere Controlled
  • 1600 C Macro TGA tube furnace with Vacuum and Atmosphere Controlled
0

1600 C Macro TGA tube furnace with Vacuum and Atmosphere Controlled

HTTF-1700 vertical tube furnace is a macro TGA tube furnace up to 1600°C function. Compared with conventional TGA devices, the TGA furnace can load larger samples up to 100 g to get a more accurate result for industry and can be operated under both vacuum and controlled gas atmosphere, even under hydrogen gas to research phase transition during material processing.

  • Price
    0
total sales0
evaluate0
Qty
- +

Pledge: genuine guarantee,speed refund,gift insurance,seven days no reason to return

  • Product Details
  • HTTF-1700 vertical tube furnace is a macro TGA tube furnace up to 1600°C function. Compared with conventional TGA devices, the TGA furnace can load larger samples up to 100 g to get a more accurate result for industry and can be operated under both vacuum and controlled gas atmosphere, even under hydrogen gas to research phase transition during material processing. The TGA furnace also may connect a gas analysis device to study gas composition change during heating and weight change.

     

    SPECIFICATIONS of Macro TGA tube furnace with Vacuum and Atmosphere Controlled

    Furnace Structure

    Using one of the HT split tube furnaces with 1600oC working temperature via MoSi2 heating elements.

    Heating zone length 390 mm with 135 mm constant temperature zone within +/- 1

    The temperature range is optional from 1200 to 1600 oC with +/- 0.1 accuracy

    Precision electronic balance with 0.001 g resolution.

    The vacuum level can reach 10-5 torr via turbopump

    Working Temperature

    900  - 1600   under oxygen & inert gas atmosphere ( PSIG 0.1 > 3 )

    900oC -  1500oC under vacuum

    Tube Size and Materials

    High purity alumina tube with a dimension of  OD60x ID54x L1200 (mm)

    Force Sensor

    High precision force sensor with 0.05% accuracy

    Resolution:   1 mg

    Sample amount: 1 g minimum; 100 g maximum.  (based on Fe powder)

    Force Sensor output data will connect to PLC or PC to show the weight change curve with temperature

    Crucibles

    Five alumina crucibles are included with 36 ml capacity (OD40xID35xH40mm)

    Please click Pic. 1 to order more

    Temperature Controllers

    Programmable temperature controller Europe there for precise control of heating rate, cooling rate and dwell time.

    Built-in PID Auto-Tune function with overheating & broken thermocouple broken protection.

    Over-temperature protection and alarm allow for operation without attendant(s).

    +/- 0.1 ºC temperature accuracy.

    One K-type thermocouple.

    RS485 Communications Port.

     Vacuum

    A KF40 vacuum port is built-in to connect a vacuum pump

    Achievable vacuum level depends on the selected vacuum pump

    Click the Picture below to order a vacuum pump separately

    Gas Delivery optional

    1/4" gas inlet and out are built-in with an optional mass flow controller. The recommended gas flow rate is <200 sccm.

    You may connect the TGA furnace with MTI multi-channel gas delivery system for mixing gas operation, or oxygen or a gas analyzer to the gas outlet port

     Warranty 

    One-year limited warranty (Consumable parts such as heating elements, processing tubes, and O-rings are not covered by the warranty, please order the replacement at related products below.)

    Dimension

    H: 1850mm L:1450mm W: 800mm

     


    HTTF-1700 vertical tube furnace is a macro TGA tube furnace up to 1600°C function. Compared with conventional TGA devices, the TGA furnace can load larger samples up to 100 g to get a more accurate result for industry and can be operated under both vacuum and controlled gas atmosphere, even under hydrogen gas to research phase transition during material processing. The TGA furnace also may connect a gas analysis device to study gas composition change during heating and weight change.

     

    SPECIFICATIONS of Macro TGA tube furnace with Vacuum and Atmosphere Controlled

    Furnace Structure

    Using one of the HT split tube furnaces with 1600oC working temperature via MoSi2 heating elements.

    Heating zone length 390 mm with 135 mm constant temperature zone within +/- 1

    The temperature range is optional from 1200 to 1600 oC with +/- 0.1 accuracy

    Precision electronic balance with 0.001 g resolution.

    The vacuum level can reach 10-5 torr via turbopump

    Working Temperature

    900  - 1600   under oxygen & inert gas atmosphere ( PSIG 0.1 > 3 )

    900oC -  1500oC under vacuum

    Tube Size and Materials

    High purity alumina tube with a dimension of  OD60x ID54x L1200 (mm)

    Force Sensor

    High precision force sensor with 0.05% accuracy

    Resolution:   1 mg

    Sample amount: 1 g minimum; 100 g maximum.  (based on Fe powder)

    Force Sensor output data will connect to PLC or PC to show the weight change curve with temperature

    Crucibles

    Five alumina crucibles are included with 36 ml capacity (OD40xID35xH40mm)

    Please click Pic. 1 to order more

    Temperature Controllers

    Programmable temperature controller Europe there for precise control of heating rate, cooling rate and dwell time.

    Built-in PID Auto-Tune function with overheating & broken thermocouple broken protection.

    Over-temperature protection and alarm allow for operation without attendant(s).

    +/- 0.1 ºC temperature accuracy.

    One K-type thermocouple.

    RS485 Communications Port.

     Vacuum

    A KF40 vacuum port is built-in to connect a vacuum pump

    Achievable vacuum level depends on the selected vacuum pump

    Click the Picture below to order a vacuum pump separately

    Gas Delivery optional

    1/4" gas inlet and out are built-in with an optional mass flow controller. The recommended gas flow rate is <200 sccm.

    You may connect the TGA furnace with MTI multi-channel gas delivery system for mixing gas operation, or oxygen or a gas analyzer to the gas outlet port

     Warranty 

    One-year limited warranty (Consumable parts such as heating elements, processing tubes, and O-rings are not covered by the warranty, please order the replacement at related products below.)

    Dimension

    H: 1850mm L:1450mm W: 800mm